| Code | Outlet duct Ø (mm) | Wall thickness (mm) (min–max) * | Maximum room area (m²)** | Operating temperature | Efficiency | |
| EVODOT160 | 160 | From 280 to 530 | 35 | -20°C ÷ 50°C | Up to 90% | |
| EVODOT100 | 100 | From 280 to 570 | 20 | -20°C ÷ 50°C | Up to 90% |
* For wall thicknesses between 240 mm and 280 mm, cut the duct and use a standard external grille, e.g. TUR125B for EVODOT100 and TUR160B for EVODOT160.
** Data calculated based on an air change rate of 0.5 vol./h, a room height of 2.70 m, one master unit and one slave unit.
Calculation example: room surface area × 2.70 m × 0.5 vol./h.
By increasing the number of slave units, the coverage area in m² can be increased.
● Helps achieve a higher energy efficiency rating
● Clean air throughout the home
● No more mould on walls
● Easy installation from inside the home
● Minimal external footprint